Question 6 of 76

Which two characteristics are associated with vSAN Data-In-Transit Encryption? (Choose two.)
Answer

Suggested Answer

The suggested answer is A, D.

Reference:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan.doc/GUID-10099331-92E7-41AF-BCAA-88DB4B4A4B7B.html
Exam 5V0-22.21: Question 6 - Image 1 AD
Community Votes2 votes
ADSuggested
100%
Question 7 of 76

An administrator must choose between deploying a virtual witness or physical witness for a vSAN Stretched Cluster. The administrator eventually decides to use a virtual witness.
What is a benefit of selecting this approach?
Answer

Suggested Answer

The suggested answer is A.

Reference:
https://core.vmware.com/blog/understanding-vsan-witness-host
Exam 5V0-22.21: Question 7 - Image 1 A
Community Votes

No votes yet

Join the discussion to cast yours

Question 8 of 76

Which two prerequisites are required before a vSAN administrator is able to use the vSAN Performance Diagnostics feature? (Choose two.)
Answer

Suggested Answer

The suggested answer is A, D.

To use the vSAN Performance Diagnostics feature, there are two main prerequisites. Firstly, the vSAN Performance Service must be enabled. This enables the collection and visibility of performance metrics on the vSAN environment. Secondly, participation in the Customer Experience Improvement Program (CEIP) must be enabled. CEIP allows VMware to collect specific information, which is necessary for vSAN Performance Diagnostics to function effectively. Thus, the two required prerequisites are enabling the vSAN Performance Service and participating in CEIP.

Community Votes10 votes
ADSuggested
100%
Question 9 of 76

During yesterday's business hours, a cache drive failed on one of the vSAN nodes. The administrator reached out to the manufacturer and received a replacement drive the following day. When the drive failed, vSAN started a resync to ensure the health of data, and all objects are showing a healthy and compliant state. The vSAN administrator needs to replace the failed cache drive.
Which set of steps should the vSAN administrator take?
Answer

Suggested Answer

The suggested answer is A.

When a cache drive in a vSAN disk group fails, the appropriate procedure is to remove the entire disk group that contains the failed cache device because vSAN does not allow the removal of just the cache disk. Following this, the physical device can be replaced. After the hardware replacement, it is necessary to verify that the ESXi host detects the new device and then manually recreate the disk group. This ensures that the new configuration is correctly recognized and used by vSAN.

Community Votes14 votes
ASuggested
100%
Question 10 of 76

Which two conditions should be verified before removing an ESXi host from a vSAN cluster? (Choose two.)
Answer

Suggested Answer

The suggested answer is B, E.

Before removing an ESXi host from a vSAN cluster, ensure that data evacuation is complete to avoid data loss or unavailability. Additionally, the ESXi host should be in maintenance mode to ensure that no active resyncs or data operations are disrupted during the removal process.

Community Votes4 votes
BESuggested