HPE Storage Solutions

Here you have the best HP HPE0-J68 practice exam questions

  • You have 32 total questions to study from
  • Each page has 5 questions, making a total of 7 pages
  • You can navigate through the pages using the buttons at the bottom
  • This questions were last updated on November 28, 2024
Question 1 of 32

Refer to the exhibit.

You are configuring a new HPE array and verifying properties of a set of volumes.

Which RAID level is used on the VMwareDatastores-GF volume?

    Correct Answer: B

    The exhibit indicates that the storage and snapshot tiers are configured as SSD 150 K (CPG: SSD_r6). The 'r6' suffix signifies that RAID 6 is being used. RAID 6 is designed to provide high data redundancy and fault tolerance, using two parity blocks for each stripe, allowing it to withstand two simultaneous drive failures. Therefore, the correct answer is RAID 6.

Question 2 of 32

A customer has completely virtualized their datacenter with VMware. You propose a SimpliVity solution to replace their aging hardware.

Which SimpliVity features should you emphasize in your presentation? (Choose two.)

    Correct Answer: A, D

    When proposing a SimpliVity solution for a fully virtualized datacenter with VMware, it is important to emphasize that SimpliVity uses native hypervisor management tools for management, which simplifies integration and management within the existing VMware environment. Additionally, the inclusion of deduplication and backup capabilities is a critical feature that enhances data efficiency and protection, providing significant value in terms of storage optimization and data management.

Question 3 of 32

Refer to the exhibit.

You are designing a new Primera solution and demonstrating performance numbers to the customer. The customer reviews the configuration and requests a change to the configuration that will increase Random Write IOPS.

Which action will satisfy the customer request?

    Correct Answer: A

    To increase Random Write IOPS, adding more disks of smaller capacity is the most effective action. This is because adding more physical disks to the RAID array increases the number of spindles, which improves the ability to handle more IOPS due to the parallelization of disk operations. Increasing the capacity of the SSDs or upgrading the base model would not directly address the need for increased IOPS, and adding more FC ports would primarily affect the data transfer rate rather than the IOPS. Therefore, option A is the correct choice to satisfy the customer's request.

Question 4 of 32

You are designing a new enterprise array solution. The customer is interested in a caching tier that provides extremely low-latency and persistent storage at the same time. They also need to support more than 500GB.

Which technology should you recommend?

    Correct Answer: C

    The appropriate technology to recommend for an enterprise array solution that requires extremely low-latency and persistent storage with support for more than 500GB is NVMe SCM. DRAM and SRAM are very fast but do not provide persistent storage. NAND SSD offers persistent storage but generally has higher latency compared to NVMe SCM. NVMe SCM, or Storage Class Memory, combines low latency and persistent storage, making it suitable for the requirements specified.

Question 5 of 32

HOTSPOT -

You need to create an N:M relationship between VMware hypervisors and virtual volumes with the least amount of administrative overhead.

Click the option where you can create a group of VMware hypervisors for volumes provisioning.

    Correct Answer: