Question 6 of 60

What is the maximum number of Bricks and drives that can be configured in a VMAX 950?
Answer

Suggested Answer

The suggested answer is C.

The maximum number of Bricks and drives that can be configured in a VMAX 950 is 8 Bricks and 1920 drives. This is based on the highest configuration specifications of the VMAX 950.

Community Votes

No votes yet

Join the discussion to cast yours

Question 7 of 60

A storage administrator has mounted a snapshot of an existing datastore to the ESXi server and decided to keep its existing signature. What action is prevented by keeping the existing signature?
Answer

Suggested Answer

The suggested answer is D.

By keeping the existing signature of a mounted datastore snapshot, the action that is prevented is increasing the datastore size. This is because the datastore treats the snapshot as an identical copy, meaning any changes such as increasing storage space would conflict with the properties of the original datastore.

Community Votes

No votes yet

Join the discussion to cast yours

Question 8 of 60

What method is used to collect host-based performance data for Windows hosts with BCSD?
Answer

Suggested Answer

The suggested answer is D.

PERFMON is the tool used to collect host-based performance data for Windows hosts. SAR and IOSTAT are typically used for Unix and Linux systems, while MMC is used for management tasks but not specifically for performance data collection. PERFMON (Performance Monitor) is a built-in Windows utility specifically designed for this purpose.

Community Votes

No votes yet

Join the discussion to cast yours

Question 9 of 60

A customer is planning to implement SRDF/Metro, using the default Device Bias method. What is a consideration?
Answer

Suggested Answer

The suggested answer is D.

When using SRDF/Metro with the default Device Bias method, one key consideration is that the state of the device pair is ActiveActive. This means both the R1 and R2 devices are accessible, and the system provides simultaneous read/write access to both devices, ensuring high availability and continuous operation.

Community Votes

No votes yet

Join the discussion to cast yours

Question 10 of 60

Which SRDF/A resiliency feature allows sessions to remain active during transient link outages?
Answer

Suggested Answer

The suggested answer is B.

The SRDF/A resiliency feature that allows sessions to remain active during transient link outages is Transmit Idle. This feature ensures that the SRDF/A mode can maintain its active state even when all links experience temporary disruptions, providing resilience against transient link outages.

Community Votes1 vote
BSuggested
100%