Question 1 of 58

What should you do to change the data protocol of a LIF?

    Correct Answer: A

    To change the data protocols associated with a Logical Interface (LIF), you must delete the LIF and recreate it. Modifying the data protocol directly is not supported; hence, recreating the LIF is the only way to apply the desired protocol changes.

Question 2 of 58

You are preparing for the installation of a new 2-node cluster with ONTAP 9.7 using NL-SAS drives. Your customer wants to use the cluster exclusively with

FlexGroups.

In this scenario, which two statements are correct? (Choose two.)

    Correct Answer: B, D

    To use FlexGroups in an ONTAP 9.7 cluster with NL-SAS drives, you need to ensure that a NAS protocol is licensed on both nodes, as FlexGroups rely on NAS protocols for data access and management. Additionally, for optimal performance and redundancy, it is crucial that the NL-SAS drives are divided evenly across both nodes in the cluster. This balance ensures that both nodes can participate in data access and management efficiently.

Question 3 of 58

You are a NetApp Professional Services engineer, employed by NetApp. You have just completed an ONTAP cluster installation. You need to collect the relevant configuration information to enable the Service Event Report (SER) to be created.

Which tool would you use to accomplish this task?

    Correct Answer: B

    To collect detailed configuration information after completing an ONTAP cluster installation, the most suitable tool is the NetAppDocs output report. This tool can provide comprehensive documentation of the system's settings in various formats, which is necessary for creating a Service Event Report (SER). Active IQ scheduled reports and Active IQ Config Advisor worksheet do not offer the same level of detailed configuration documentation required for this task, and the ONTAP System Manager is more suited for management tasks rather than producing detailed configuration reports.

Question 4 of 58

What is the default shelf ID for disk shelves with IOM12 modules?

    Correct Answer: D

    The default shelf ID for disk shelves with IOM12 modules is 00. This configuration is set by the manufacturer and is a standard reference in documentation for these types of shelves.

Question 5 of 58

After completing the installation of an AFF A800 ONTAP AI cluster, you are asked which contacts are available for additional help in obtaining immediate assistance in solving P1 issues.

In this scenario, what do you tell the customer?

    Correct Answer: C

    In a scenario involving critical issues like P1 problems, the most immediate and effective method to obtain assistance is to contact NetApp Support by telephone. This ensures direct and rapid communication with support personnel who can immediately begin addressing the issue, which is crucial for high-severity problems.