Question 1 of 57

Refer to the exhibit, which contains a TCL script configuration on FortiManager.

An administrator has configured the TCL script on FortiManager, but the TCL script failed to apply any changes to the managed device after being run.

Why did the TCL script fail to make any changes to the managed device?

    Correct Answer: A

    The TCL script fails to make any changes to the managed device because the TCL procedure 'run_cmd' has not been created. The script defines a procedure 'do_cmd', but later in the script, it calls 'run_cmd', which is undefined. To rectify this, the procedure name should be consistent throughout the script.

Question 2 of 57

You want to improve reliability over a lossy IPSec tunnel.

Which combination of IPSec phase 1 parameters should you configure?

    Correct Answer: A

    To improve the reliability of a lossy IPSec tunnel, the configuration of 'fec-ingress' and 'fsc-egrsss' is appropriate. Forward Error Correction (FEC) can help mitigate packet loss issues over unreliable networks by adding redundancy that allows the receiver to reconstruct lost packets, thereby enhancing the reliability of the connection.

Question 3 of 57

How are bulk configuration changes made using FortiManager CLI scripts? (Choose two.)

    Correct Answer: B, D

    Bulk configuration changes using FortiManager CLI scripts can be made by running the scripts directly on the Remote FortiGate device, where administrators do not have the option to review changes prior to installation. Additionally, when making changes to the Policy Package, ADOM database, it is necessary to use the installation wizard to apply the changes to the managed FortiGate device. Running scripts on the Remote FortiGate directly ensures immediate implementation, whereas using the installation wizard for the Policy Package, ADOM database ensures that changes are properly methodized and reviewed before being applied.

Question 4 of 57

Refer to the exhibit, which contains a partial configuration of the global system.

What can you conclude from this output?

    Correct Answer: C

    The configuration uses 'set check-protocol-header loose' which implies that the protocol header check is not strict. Enabling strict header checking would disable all hardware acceleration including NP and CP processing, but since the configuration is set to loose, all hardware acceleration remains enabled. Therefore, NPs (Network Processors) and CPs (Content Processors) are enabled.

Question 5 of 57

Refer to the exhibits, which show the configurations of two address objects from the same FortiGate.

Engineering address object -

Finance address object -

Why can you modify the Engineering address object, but not the Finance address object?

    Correct Answer: C

    The reason why you can modify the Engineering address object, but not the Finance address object, is that FortiGate joined the Security Fabric, and the Finance address object was configured on the root FortiGate. When an address object is created on the root FortiGate in Security Fabric mode, it is synchronized to downstream devices, and these downstream devices cannot modify it. The 'OK' button will not be available, and only the 'Return' button will be present for such objects on downstream devices.